Filter Results By:
Products
Applications
Manufacturers
Magnetic Field
an force around magnets, electric current and atomic orbits.
See Also: Magnetic, Magnetic Test, Magnetic Head, Magnetic Susceptibility, Magnetic Flux, Magnetic Stripe, Magnetic Permeability, H-field, Magnetic Field Mapping, Magnetic Field Meters, Magnetic Field Probes, Magnetic Field Sensors, Magnetic Field Test, Helmholtz Coils
-
product
Magcam MiniCube1D
Magcam's MiniCube1Dmagnetic field camera provides quantitativeBz magnetic field mapping in a 12.7mm x 12.7mm 2D planewith 0.1mm spatial resolution, measured at high speed. The camera is based on Magcam's unique integrated 2D Hall sensor array technology, featuring more than 16000 microscopic magnetic field sensors on one single chip. Each sensor independently measures the local magnetic field, resulting in quantitative2D magnetic field maps with high spatial resolution, measured athigh speed. These magnetic field maps contain a large amount of information about the magnet's properties, which can be extracted using Magcam's powerful MagScope measurement and analysis software.
-
product
RF Helmholtz Coil
The Beehive Electronics 135A RF Helmholtz coil generates a well-controlled, uniform magnetic field. It can be used to calibrate magnetic field probes, such as the Beehive 100 series, or for testing the susceptibility of other devices to magnetic fields. The Helmholtz coil comes supplied with a fixture that makes it easy to calibrate Beehive 100 series probes.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF6 set
The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Hall Effect Portable Gauss-Meters
300 Series
Integrity Design and Reseach Corp.
Typical Applications include Measurements of the Earth's field vectors, Air shipment inspection, Mapping and recording field perturbations, Magnet classification, Analysis of magnetic circuitry and components, Magnetic Resonance Imaging (MRI) and Measuring residual fields.
-
product
Mechanical Shock Test System
BW-MST-E5000
The Mechanical Shock Tower develops the kinetic energy electromagnetically. An iron core "bullet" is attracted to the magnetic core of the solenoid by the dense magnetic field that is created as current flows through the field coil of the shock tower. As the bullet is drawn into the center of the magnetic field the acceleration increases exponentially as the gap reduces to zero on impact causing the high impact shock
-
product
Magnetic Encoders
The magnetic encoder detects rotational position information as changes of the magnetic field, converts them into electrical signals, and outputs them. The simplest magnetic encoder consists of a permanent magnet and a magnetic sensor.
-
product
Intelligent Digital Gauss Meter / Tesla Meter
DX-160
DX-160 Full-digital high-precision gaussmeter/teslameter is designed for high-test precision, high-resolution magnetic field test applications. It provides a wide-range measurement from DC to up to 50kHz AC magnetic field measurement.
-
product
Reference Magnet
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
10-Channel Field-Strength-Meter
H10
10-Channel tabletop-unit for constant and alternating magnetic field.
-
product
7-Channel Field-Strength-Meter
H7
7-Channel tabletop-unit for constant and alternating magnetic field.
-
product
Electromagnetic
Promis 10
The Promis device is a multi-frequency, multi-spacing 3 component slingram type EM System for sounding and profiling the soil. This system features a transmitter loop to produce a primary magnetic field that will induce eddy current in conductive materials. These eddy currents will generate a secondary magnetic field that will be measured with the receiver loop. This system measures the in-phase and the out-of-phase components of the secondary magnetic field.
-
product
Magnetometer
were developed for extremely sensitive measurements of small magnetic fields, such as biomagnetic fields from the heart and brain.
-
product
Fluxgate Magnetometer Fluxmaster
Hand-held instrument for precise measurement of weak magnetic field from 0.1 nT to 200 µT (DC to 1 kHz). Typical applications are: Measurement of the Earth's magnetic field vector components, detection of AC fields from power lines, paleomagnetic investigations, package inspection according to IATA 953, and residual field measurement.
-
product
Vacuum Interrupter Pressure Integrity Test Set
Low Drift Current is measured by applying magnetic field.
-
product
Measuring and Calibration Stations
PCB
Is used to measure electric and magnetic fields of an ESD generator
-
product
Ammeter
DC Moving Coil Meter
It uses magnetic deflection, where current passing through a coil placed in the magnetic field of a permanent magnet causes the coil to move.
-
product
Teslameter
RX - 213
Teslameter RX-213 is a portable, hall-effect magnetic field meter, measuring simultaneously - along three mutually perpendicular axes - both the DC component and the variable component of the field (AC) with a frequency of 20 Hz - 20 kHz. The latter quantity is measured as the effective value of the magnetic field (so-called true RMS ), regardless of changes in the field as a function of time.
-
product
Radiating Loops
The magnetic, handheld coil was designed to generate defined mag-netic fieldstrength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields.
-
product
MagScope Software
MagScope is Magcam's advanced data analysis software formeasuring and analyzing magnetic field distributions.MagScope is designed to extract as much informationas possible from the measurement data. MagScope is integrated in and optimized for all our magnetic field cameras and scanners.
-
product
Electromagnetic Radiation Tester
Model KM 196
Kusam Electrical Industries Limited
• Unit : Electric Field : V/m; Magnetic Field : mT• Precision : Electric Field : 1V/m; Magnetic Field : 0.01 mT• Range : Electric Field : 1V/m ~ 1999V/m.• Magnetic Field : 0.01 mT ~ 19.99 mT• Alarm Threshold : Electric Field : 40V/m, Magnetic Field : 0.4 mT• Reading Display : 3½ Digit Digital LCD display with Backlight.• Frequency Range : 5Hz ~ 3500MHZ• Sampling Time : About 0.4 second.• Measuring Mode : Dual Mode• Overload Alert : “1” appears on LCD• Sound & Light Alarm• Data Hold function.• Auto Power Off.• Average & Peak measurement.• Low Battery Indication.• Operating Temperature & Humidity : 0°C ~ 50°C; below 80%RH.• Power battery : 9V Battery.• Dimension : 63.6 x 31 x 125.8mm• Weight : Approx. 146g.
-
product
Zero Gauss Chamber
IDR-800
Integrity Design and Reseach Corp.
Two cylindrical tubes are equal in length (12"), one is inside the other, both of them are closed at one end. At the other end, the inner tube is open (Radius=1").The cylindrical tubes are made from high permeability material.The magnetic field inside the inner tube is almost annulled.Optional use with the Geomagnetometer IDR-321 to provide a zero gauss (magnetic field-free environment) reference, enabling you to take absolute readings of the ambient magnetic field (the Earth's magnetic field is typically around 500 mG)
-
product
Vector Field and Multi-Axis Systems
Cryogenic vector magnet systems allow precise alignment of the magnetic field to an exact direction in a measurement sample. The system provides the capability of orienting the magnetic field to any vector direction. This is suitable for experiments where samples cannot be moved easily.
-
product
Electro Magnetic Meter
This meter is used to indicate radiated electromagnetic fields. Wherever there is a voltageor a current, electric (E) and magnetic (H) fields arise.
-
product
Conditioners And Demagnetizers
A conditioner is a device that is used to selectively adjust the magnetic strength of a part to a specified value. In the past, conditioners have been used to simply “knock-down” the magnetic field of low-coercivity magnet parts (such as alnico and ferrite) until a certain field level was achieved. The resulting part was slightly weaker, but had a field strength that was repeatable.
-
product
Automated Systems
A conditioner is a device that is used to selectively adjust the magnetic strength of a part to a specified value. In the past, conditioners have been used to simply “knock-down” the magnetic field of low-coercivity magnet parts (such as alnico and ferrite) until a certain field level was achieved. The resulting part was slightly weaker, but had a field strength that was repeatable.
-
product
Electrical Steel Tester
C 510
Dr. Brockhaus Messtechnik GmbH & Co. KG
The sample is exposed to a defined magnetic field within a measuring coil. A magnetic flux is created inside the material. The required current is supplied by a power amplifier.
-
product
Fully Automatic MRAM Probe System
*This system can measure MRAM characteristics automatically.*Generates strong and constant magnetic fields. (Max 1.5T, the highest in the industry)*Performs high speed sweep of magnetic field by using non-magnetic materials wafer chuck. (Max 4Hz, ±1T, the highest in the industry)
-
product
*Teslameter
RX-21b
The RX-21 Teslameter is a portable, hall-effect magnetic field meter that measures both the DC component and the AC component of the field. The latter quantity is measured in the frequency range 20 Hz - 25 kHz as the effective value of the magnetic field (so-called true RMS), regardless of changes in the field as a function of time. The meter's operating range is 0 - 3000 mT , switched manually or automatically.
-
product
Teslameter
RX-21b
The RX-21 Teslameter is a portable, hall-effect magnetic field meter that measures both the DC component and the AC component of the field. The latter quantity is measured in the frequency range 20 Hz - 25 kHz as the effective value of the magnetic field (so-called true RMS), regardless of changes in the field as a function of time. The meter's operating range is 0 - 3000 mT , switched manually or automatically.